Alle Kategorien
Ihr Warenkorb
Process Multimeter VICTOR 79+
Artikel-ID #VC79
Listenpreis: $489.99
Preis: $279.99
Mengenbereich (Einheit) Preis (pro Einheit) Rabatt
5 $249.99 $30.00
10 $229.99 $50.00
Menge: Einheit(s)
Beschreibung:
Features:
  • Process Meter is a handheld, battery-orperated tool for measuring electrical parameters.
  • It has all the features of digital multimeter (besides the feature of RTD and ID), it could also output signals of direct voltage, current, resistance, temperature and frequency as well.
  • Auto/manual range switch, Measure value display hold
  • The thermocouple high accuracy could-endc can auto offset
  • Panel auto calibrated
  • The function of auto close backligh and auto power-off
  • Large LCD include white LED backlight
  • It is easy to operation by user, cabinet and solid adapt to be used at locale.

 

Specifications:

 

 

Meansuring function

Range

Measuring range

Resolving power

Accuracy

Remark

DC Voltage

4V

-4.000V~4.000V

1mV

0.2%+4

Input impedance:10MΩ

 

40V

-40.00V~40.00V

0.01V

0.2%+4

400V

-400.0V~400.0V

0.1V

0.2%+4

AC Voltage

400mV

0~400.0mV

0.1mV

1%+4

Input impedance:10MΩ

<100pF

4V

0~4.000V

1mV

0.5%+4

40V

0~40.00V

0.011V

0.5%+4

400V

0~400.0V

0.1V

0.5%+4

DC Mv Voltage

40mV

-40.00mV~40.00mV

0.01mV

0.2%+4

Input impedance:10MΩ

400mV

-400.0mV~400.0mV

0.1mV

0.2%+4

OHM

400Ω

0~400.0Ω

0.1Ω

0.2%+4

Plough voltage:0.4V

Not including the accuracy of down-lead resistance

4kΩ

0~4.000kΩ

0.2%+4

40kΩ

0~40.00kΩ

0.01kΩ

0.2%+4

400kΩ

0~400.0kΩ

0.1kΩ

0.2%+4

4MΩ

0~4.000MΩ

1kΩ

0.2%+4

40MΩ

0~40.00MΩ

0.01MΩ

1%+4

DC Current

40mA

-40.00mA~40.00mA

0.01mA

0.2%+4

Input impedance:1Ω

400mA

-400.00mA~400.00mA

0.1mA

0.2%+4

AC Current

40mA

0~40.00mA

0.01mA

0.5%+4

Input impedance:1Ω

400mA

0~400.00mA

0.1mA

0.5%+4

Frequency

50Hz

0~50.0 Hz

0.01Hz

0.1%+3

 

500Hz

0~500.0 Hz

0.1Hz

0.1%+3

5kHz

0~5.000 kHz

1Hz

0.1%+3

50kHz

0~50.00k Hz

0.01kHz

0.1%+3

100kHz

0~100.0k Hz

0.1kHz

0.1%+3

Duty cycle

0.1%~99%

 

0.1%

1%

 

Diode test

1V

 

0.001V

10%

Plough voltage 1.1V~1.6V

Current of short circuit:0.6mA

Continuity test

≤50ΩBB

 

0.1Ω

 

Thermocouple

R

-40'C~1760'C

1'C

0.5%+3(≤100'C) 0.5%+2( >100'C)

Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error:±2'C

S

-20'C~1760'C

K

-200'C~950'C

0.2%+2(≤100'C)

0.5%+1( >100'C)

E

-200'C~500'C

J

-200'C~700'C

T

-200'C~400'C

N

-200'C~1000'C

0.5%+3(400~600'C)

 0.5%+2( >600'C)

B

400'C~1800'C

Thermo resistance

Pt100

-200'C~700'C

1'C

0.5%+2

Pt100-385 thermometric scale. Not including the accuracy of down-lead resistance

Cu50

-50'C~150'C

0.5%+4

 

Output function:

 

Function

Range

Setting range

Resolving power

Accuracy

Remark

OHM

400Ω

0~400.0Ω

0.1Ω

0.2%+4

±1mAcurrent not includingthe accuracy of down-lead resistance

DCmV

100mV

-10.00mV~110.00mV

0.01mV

0.2%+4

Max output current:5mA

DCV

5V

-0.5000V~5.5000V

1mV

0.2%+4

Max output current5mA

FREQ

100Hz

1.0Hz~110.0Hz

0.1Hz

0.2%+2

50% Duty cycle 5V p-p

1kHz

0.100Hz~1.100Hz

0.001kHz

0.2%+2

10kHz

1.0kHz~11.0kHz

0.1kHz

0.2%+2

Analog transducer XMT

-20mA

0~-22.000mA

0.01mA

0.2%+4

Outside power supply 28V when 20mA 1kΩresistance

DC Mv

20mA

0~22.000mA

0.01mA

0.2%+4

Outside power supply 15V when 20mA

400Ω resistance

Thermocouple

R

-40'C~1760'C

 

1'C

0.2%+3

(≤100'C)

0.2%+2

( >100'C)

Adopt ITS-90 thermometric scale not including the accuracy of RJC error RJC error:  ±2'C

S

-20'C~1760'C

0.1'C

K

-200'C~1370'C

0.2%+20

(≤-100'C)

0.2%+10

( >-100'C)

E

-200'C~1000'C

J

-200'C~1200'C

T

-200'C~400'C

N

-200'C~1300'C

B

400'C~1800'C

1'C

0.2%+3

(400~600'C)

0.2%+2

( >600'C)

Thermo resistance

Pt100

-200'C~850'C

0.1'C

0.2%+6

Pt100-385 thermometric scale±1mA not including the accuracy of down-lead resistance

Cu50

-50'C~150'C

 

 

Monkey Lin
Lin
Lin
Lin
Xia Lin