Qty.Range(unit) | Price(per unit) | Discount |
5 | $1250.00 | $150.00 |
10 | $1150.00 | $250.00 |
50 | $1100.00 | $300.00 |
measurement function
|
range
|
measurement range
|
resolution
|
accuracy
|
remark
|
DC voltage
DCV |
50mV
|
-5.000mV~
55.000mV |
1μV
|
0.01+0.01
|
Input resistance: about 100MΩ
|
500mV
|
-50.00mV~
550.00mV |
10μV
|
0.01+0.01
|
||
5V
|
-0.5000V~
5.5000V |
0.1mV
|
0.01+0.01
|
Input resistance: about 1MΩ
|
|
30V
|
-5.000V~
35.000V |
1mV
|
0.01+0.01
|
||
DC current
DCI |
50mA
|
-5.000mA~
55.000mA |
1μA
|
0.01+0.01
|
shunt resistance: about 10Ω
|
Ohms
OHM (4W) |
500Ω
|
0.00Ω~550.00Ω
|
0.01Ω
|
0.01+0.01
|
500Ω about 1mA simulation
5KΩ about 0.1mA simulation open-loop voltage: about 2.5V wire resistance is excluded in the accuracy |
5KΩ
|
0.0000 KΩ~
5.5000KΩ |
0.1Ω
|
0.01+0.01
|
||
frequency
FREQ |
50KHz
|
3Hz~50.00000KHz
|
0.01Hz
|
0.01+0.00004
|
input resistance: more than 100 kΩ
frequency sensitivity: square wave is 3V Vp-p at least 50% duty ratio |
CPM
|
180~3000000 CPM
|
1CPM
|
±2个字
|
||
Thermal couple
TC |
R*
|
0°C~1767°C
|
1°C
|
0~500℃ : 1.8℃
500~1767℃ : 1.5℃ |
Employ ITS-90 temperature standard
Errors for cold-end compensation is excluded in the accuracy |
S*
|
0°C~1767°C
|
||||
K
|
-100.0°~1372.0°C
|
0.1°C
|
-100.0~0.0℃ : 1.2℃
0.0~1372.0℃ : 0.8℃ |
||
E
|
-50.0°C~1000.0°C
|
-50.0℃~0.0℃ : 0.9℃
0.0~1000.0℃ : 1.5℃ |
|||
J
|
-60.0°C~1200.0°C
|
-60.0~0.0℃ : 1.0℃
0.0~1200.0℃ : 0.7℃ |
|||
T
|
-100.0°C~400.0°C
|
-100.0~0.0℃ : 1.0℃
0.0~400.0℃ : 0.7℃ |
|||
N
|
-200.0°~1300.0°C
|
-200.0~0.0℃ : 1.5℃
0.0~1300.0℃ : 0.9℃ |
|||
B*
|
600°C~1820°C
|
1°C
|
600~800℃ : 2.2℃
800~1000℃ : 1.8℃ 1000~1820℃ : 1.4℃ |
||
L
|
-60.0°C~900.0°C
|
0.1°C
|
-60.0~0.0℃ 0.7℃
0.0~900.0℃ 0.5℃ |
||
U
|
-100.0°C~600.0°C
|
0.1°C
|
-100.0~0.0℃ 0.7℃
0.0~600.0℃ 0.5℃ |
||
Resistance temperature
RTD |
Pt100
385 |
-200.0°C~800.0°C
|
0.1°C
|
-200.0~0.0℃ : 0.5℃
0.0~400.0℃ : 0.7℃ 400.0~800.0℃ : 0.8℃ |
Employ ITS-90 temperature standard
Errors due to the mismatch of lead resistance for lead resistance, 3-wired or 4-wired measurements are excluded in the accuracy |
Pt1000
385 |
-200.0°C~630.0°C
|
-200.0~100.0℃: 0.3℃
100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ |
|||
Pt200
385 |
-200.0°C~630.0°C
|
-200.0~100.0℃: 0.8℃
100.0~300.0℃ : 0.9℃ 300.0~630.0℃ : 1.0℃ |
|||
Pt500
385 |
-200.0°C~630.0°C
|
-200.0~100.0℃: 0.4℃
100.0~300.0℃ : 0.5℃ 300.0~630.0℃ : 0.7℃ |
|||
Cu10
|
-100.0°C~260.0°C
|
1.8℃
|
|||
Cu50
|
-50.0°C~150.0°C
|
0.7℃
|
|||
Pulse counting
PULSE |
100000 cycles
|
1~100000cycles
|
1cycle
|
±2个字
|
see the related indexes for frequency
|
switch volume measurement
SWITCH |
|
CLOSE / OPEN
|
|
|
about 1mA simulation
short circuit displays CLOSE open circuit displays OPEN the threshold value is about 200~300Ω |
Continuity test
CONNECT |
500Ω
|
≤ 50Ω vocalize
|
0.01Ω
|
|
500Ω
about 1mA simulation |
Loop supply
LOOP |
24 V
|
|
|
10%
|
short circuit protection
Max circuit : 22 mA Max input voltage: 30 V DC output resistance: 250Ω nominal value |