See All Categories
Your Shopping Cart
VICTOR 60F 2500V Digital Insulation Resistance Tester High Voltage Megohmmeter
Item ID #VICTOR 60F
List Price: $150.00
Price: $120.00
Qty.Range(unit) Price(per unit) Discount
50 $80.00 $40.00
Quantity: Unit(s)
Description:
VICTOR 60F 2500V Digital Insulation Resistance Tester High Voltage Megohmmeter
Overload Protection Insulation resistance function: AC1200V/10 seconds; voltage function: AC720V/DC1000V/10 seconds
Legal Conformity IEC61010-1(CAT Ⅲ 600V,POLUTION degreeⅡ) 
IEC61557-1,2(electronic safety requirements for low voltage distribution system below AC 1000V and DC 1500V
Electromagnetic Compatibility conforms to IEC61326-1,Group 1,Class B
Surge Protection 6kV (as per IEC61010.1-2001)
Identification Mark CE
Quality Standard develops ,designs and manufactures as per ISO 9001
 
General Feature
Display Screen digit: displays in 2000 digits;
white backlight
Operation Temperature and Moisture Range 0~40 ºC,relative moisture≤85%(no condensation)
Storage Temperature and Moisture Range -20 ºC~60 ºC,relative moisture≤90%( no condensation)
Accuracy Required Temperature and Moisture Range 23±5ºC,relative moisture≤75%( no condensation)
Ambient Condition for Operation Indoor,outdoor operation(no waterproof),at an altitude of 0~2,000 meter
Stored Data 100 groups
Indicator for Over-range Voltage: OL; Insulation resistance: > 1999
Battery Type eight 1.5V Alkaline (LR6) batteries
Low Battery displays battery mark
Automatic Power-off The default value is 5 minutes if no operation ,and adjustable.
Closed – case Calibration no internal adjustments needed
Measurement 178(L)×110(W)×59(D)mm
Weight about 500g
Calibration Period One year
 
 Measurement Range and Accuracy
Error limits are given as:±( [ % of reading ]+[ number of least significant digits ]),warranty for one year. (Note: ‘number of least significant digits’ means the digits increased or decreased in least significant digits)
Ambient temperature: 23±5ºC ; Ambient moisture: 45~75%RH
Insulation Resistance Measurement(RISO)
Rated voltage Measurement range Open-circuit voltage Rated measured current Accuracy
50V 0~1.999MΩ DC 50V
+10% , -10%
1mA nominal value
40kΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
100V 0~1.999MΩ DC 100V
+10% , -10%
1mA nominal value
100kΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
200~500MΩ
250V 0~1.999MΩ DC 250V
+10% , -10%
1mA nominal value
250kΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
200~1999MΩ
500V 0~1.999MΩ DC 500V
+20% , -0%
1mA nominal value
500kΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
200~1999MΩ
2.00~5.00GΩ
1000V 0~1.999MΩ DC 1000V
+20% , -0%
1mA nominal value
1MΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
200~1999MΩ
2.00~9.99GΩ
1500V 0~1.999MΩ DC 1500V
+20% , -0%
1mA nominal value
1.5MΩ load
5%+3
2.00~19.99MΩ
20.0~199.9MΩ
200~1999MΩ
2.00~9.99GΩ
10.0~19.9GΩ
2000V 0~19.99MΩ DC 2000V
+20% , -0%
1mA nominal value
2MΩ load
5%+3
20.0~199.9MΩ
200~1999MΩ
2.00~9.99GΩ
10.0~50.0GΩ
2500V 0~19.99MΩ DC 2500V
+20% , -0%
1mA nominal value 2.5MΩ load 5%+3
20.0~199.9MΩ
200~1999MΩ
2.00~9.99GΩ
10.0~99.9GΩ
l Short circuit measurement current of insulation measurement: 1.5 mA nominal value
l Automatic discharge time of insulation measurement: when the capacitance C = 1μF or lower, discharge time <1 second.
l Maximum capacitive load of insulation measurement: available for any operation when the value is below 1μF.
 
 
 
Voltage Monitoring Display (insulation resistance range)
Voltage range Measurement range Accuracy
2500V 0~2500V 2%+3
 
AC/DC Voltage Measurement
Measurement function D/C voltage A/C voltage
Measurement range 0~±1000V 30~750V(45~200Hz)
Resolution ratio 1V
Accuracy 2%+3
l Output impedance: 10MΩ.
l Measurement speed rate: about 2 times / s
Monkey Lin
Lin
Lin
Lin
Xia Lin